Whatsapp
People often compare the 10kWh Home Battery Energy Storage System for Backup and Solar by kilowatt-hours, but that is only half of the purchase decision. The other half is whether the battery can communicate with the inverter already installed. If it cannot, the battery may not operate as intended.
The 10kWh Home Battery Energy Storage System for Backup and Solar range covers both sides. Six capacities from 2.56kWh to 10.24kWh allow sizing to measured household consumption rather than a nominal figure. Three voltage platforms — 25.6V, 48V and 51.2V — match common hybrid inverter input ranges.
Communication is RS485, RS232 and CAN as standard on every variant, with WiFi, 4G and Bluetooth available as options. Cells are LFP in aluminium cases, rated beyond 6000 cycles at 0.5C and 25°C with at least 80% capacity retained.
For the 10kWh Home Battery Energy Storage System for Backup and Solar, 2.56kWh comes two ways: 25.6V100Ah (8S1P) or 51.2V50Ah (16S1P). Same energy, different voltage; selection should be based on the inverter's DC input window rather than price.
4.8kWh (48V100Ah, 15S1P) and 5.12kWh (51.2V100Ah, 16S1P) share the 440*585*170mm body at 42kg and 46kg respectively. The 48V unit suits older inverters specified around a 40.5-54VDC window.
9.6kWh (48V200Ah) and 10.24kWh (51.2V200Ah) step up to 540*800*170mm at 80kg and 85kg, and raise standard discharge current from 50A to 100A.
Maximum discharge is 100A on the smaller four units and 105A on the 200Ah pair; this determines whether the battery can carry a heavy simultaneous load.
One exception: the 51.2V50Ah variant charges at a maximum of 50A, half the 100A of the other small units. This matters with a large array producing surplus quickly.
Every variant has a 12g aerosol suppression device inside the pack, natural cooling with no fans, and 5-10 year warranty.


|
Parameter |
25.6V100Ah |
51.2V50Ah |
48V100Ah |
51.2V100Ah |
48V200Ah |
51.2V200Ah |
|
Cells combination |
8S1P |
16S1P |
15S1P |
16S1P |
15S1P |
16S1P |
|
Battery pack capacity |
2.56kWh |
2.56kWh |
4.8kWh |
5.12kWh |
9.6kWh |
10.24kWh |
|
Standard discharge current |
50A |
50A |
50A |
50A |
100A |
100A |
|
MAX. discharge current |
100A |
100A |
100A |
100A |
105A |
105A |
|
Working voltage range |
20~29.2VDC |
43.2~57.6VDC |
40.5~54VDC |
43.2~57.6VDC |
40.5~54VDC |
43.2~57.6VDC |
|
Standard Voltage |
25.6VDC |
51.2VDC |
48VDC |
51.2VDC |
48VDC |
51.2VDC |
|
MAX. charging current |
100A |
50A |
100A |
100A |
105A |
105A |
|
MAX. charging voltage |
29.2V |
57.6V |
54V |
57.6V |
54V |
57.6V |
|
Discharge depth and life |
>6000 times (0.5C@25°C) Energy retention rate ≥ 80% |
>6000 times |
>6000 times |
>6000 times |
>6000 times |
>6000 times |
|
Working humidity |
65±20%RH |
65±20%RH |
65±20%RH |
65±20%RH |
65±20%RH |
65±20%RH |
|
Operating temperature |
0~+40°C |
0~+40°C |
0~+40°C |
0~+40°C |
0~+40°C |
0~+40°C |
|
Working altitude |
≤2500m |
≤2500m |
≤2500m |
≤2500m |
≤2500m |
≤2500m |
|
Firefighting |
Aerosol PACK 12g |
Aerosol PACK 12g |
Aerosol PACK 12g |
Aerosol PACK 12g |
Aerosol PACK 12g |
Aerosol PACK 12g |
|
Cooling method |
Natural cooling |
Natural cooling |
Natural cooling |
Natural cooling |
Natural cooling |
Natural cooling |
|
Installation method |
Wall-mounted installation |
Wall-mounted installation |
Wall-mounted installation |
Wall-mounted installation |
Wall-mounted installation |
Wall-mounted installation |
|
IP rating |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
|
Warranty |
5-10Years |
5-10Years |
5-10Years |
5-10Years |
5-10Years |
5-10Years |
|
Communication |
Default: RS485/RS232/CAN(Optional WIFI/4G/Bluetooth) |
RS485/RS232/CAN |
RS485/RS232/CAN |
RS485/RS232/CAN |
RS485/RS232/CAN |
RS485/RS232/CAN |
|
Certification |
CE ROHS FCC UN38.3 MSDS ISO9001 |
CE ROHS FCC |
CE ROHS FCC |
CE ROHS FCC |
CE ROHS FCC |
CE ROHS FCC |
|
Product size |
440*460*170mm |
440*460*170mm |
440*585*170mm |
440*585*170mm |
540*800*170mm |
540*800*170mm |
|
Package size |
500*520*230mm |
500*520*230mm |
500*630*240mm |
500*630*240mm |
600*860*230mm |
600*860*230mm |
|
Net weight |
26.5kg |
30kg |
42kg |
46kg |
80kg |
85kg |
|
Gross weight |
32kg |
36kg |
50kg |
54kg |
86kg |
92kg |
Start with evening and overnight consumption, not your daily total. Daytime load is served by the array; the battery covers the hours when panels produce nothing. Pull that figure from your meter over a full week.
A household using 4-6kWh between sunset and sunrise is well served by the 5.12kWh unit. Consumption in the 8-10kWh range points to the 10.24kWh model.
Then check against the array. A battery larger than your daily surplus generation will sit part-charged most of the year, which can result in unnecessary cost and reduced cycle utilisation. A 3kW array in a temperate climate rarely justifies 10.24kWh of storage.
For the 10kWh Home Battery Energy Storage System for Backup and Solar, compatibility comes down to two checks. First, voltage: your inverter's battery input range must contain the pack's working window — 20~29.2VDC for the 25.6V unit, 40.5~54VDC for the 48V units, and 43.2~57.6VDC for the 51.2V units.
Second, protocol. The BMS supports RS485, RS232 and CAN; CAN is commonly used by hybrid inverters. Provide the inverter make and model before ordering so the protocol mapping can be confirmed or a configuration file supplied.
Without communication, the battery may still charge and discharge, but the inverter cannot read state of charge or enforce the BMS current limits. Voltage-based management can accelerate aging and does not provide a usable SOC reading in the app.
LFP chemistry in aluminium-cased prismatic cells — the case contains cell swelling that pouch formats vent. This is relevant for a battery mounted inside a house.
Each pack contains a 12g aerosol suppression unit that discharges inside the enclosure at the earliest stage of a thermal event, before it can propagate between cells.
The 25.6V100Ah variant is certified to CE, ROHS, FCC, UN38.3, MSDS and ISO9001; the remaining variants carry CE, ROHS and FCC.
UN38.3 testing and the MSDS are required by freight forwarders and customs for lithium shipments; both are issued with every order.
Every pack is capacity-graded and internal-resistance matched before series assembly. In a 16S string one weak cell caps the usable capacity of all sixteen.
Each unit completes a full charge and discharge cycle on test before packing, with the BMS log retained against the serial number.
1. Cell intake — every batch is sampled for capacity, internal resistance and open-circuit voltage against the supplier's declared figures.
2. Grading and matching — cells are binned so each pack is built from a narrow performance band rather than mixed stock.
3. Busbar welding — series connections laser-welded and pull-tested; a poor weld surfaces years later as a hot joint.
4. BMS integration — board fitted, balancing leads routed and verified cell by cell before the enclosure closes.
5. Enclosure assembly — sheet metal formed and powder-coated in-house, LCD and aerosol suppression device installed.
6. Firmware and protocol loading — RS485, RS232 and CAN tested against reference inverter hardware.
7. Full cycle test — one complete charge and discharge at rated current with cell-level voltage and temperature logged.
8. Packing — foam-cushioned carton, UN3480 dangerous-goods labelling applied, then palletised for export.
It is intended for indoor mounting. IP20 provides protection against fingers and solid objects above 12mm and no protection against water. Suitable locations include a garage, utility room, basement or plant room.
The operating window is 0~+40°C with humidity at 65±20%RH and altitude up to 2500m. An unheated garage in a climate that drops below freezing will hold the battery outside its charging range through winter. The BMS will refuse charging below 0°C, which is normal protective behaviour rather than a fault.
If the only viable location is outdoors, an IP-rated outdoor cabinet is required; this product is not intended for outdoor installation.
Cycle life should be stated with rate, temperature and retention together. For this range it is >6000 cycles at 0.5C and 25°C to 80% retention; a cycle number without those qualifiers is incomplete.
Confirm the IP rating and permitted installation location. IP20 packs are indoor-only.
Confirm whether the BMS protocol for the specific inverter is verified or only described as compatible with most brands. We confirm the model or state that it is untested.
Warranty coverage should be stated: calendar years, cycles, or retained capacity. This range carries 5-10 years depending on configuration and market.
Commercial terms: MOQ is 1 unit for standard variants. OEM and ODM are available for cell brand, voltage, dimensions and housing colour; lead time extends for customised builds.
Packaged dimensions run 500*520*230mm for the 2.56kWh units at 32kg and 36kg gross, 500*630*240mm for the 4.8kWh and 5.12kWh units at 50kg and 54kg, and 600*860*230mm for the 9.6kWh and 10.24kWh units at 86kg and 92kg gross. The largest variants require a two-person lift onto a wall bracket.
Cartons are foam-cushioned with the pack immobilised, and every carton carries UN3480 class 9 labelling. Sea freight requires a dangerous-goods booking. The declaration is prepared, and the UN38.3 report and MSDS travel with the documents.
Terms are EXW, FOB Ningbo or Shanghai, and CIF. Air freight works for samples under lithium state-of-charge rules, though most distributors consolidate by sea. Allow extra time for dangerous-goods scheduling.
Warranty runs 5-10 years by variant and market, covering cells, BMS, LCD and enclosure as one unit.
Capacity loss is gradual; beyond 6000 cycles at 0.5C the pack retains at least 80%. A reading slightly below nameplate after three years is normal.
Faults can be diagnosed from the BMS log read over RS485 or CAN. The export file allows the affected cell group to be identified without a site visit.
Replacement packs ship from stock; on multi-pack installations a single unit can be swapped while the rest of the bank continues operating.
No routine maintenance is required. An annual visual check of terminals, mounting bolts and ventilation clearance is recommended.
Incorrect: fixing an 85kg pack to plasterboard. Correct: mount to masonry or a rated steel frame, with fixings checked against the variant's gross weight.
Incorrect: installing in an unheated garage in a cold climate. Correct: the charging window starts at 0°C. Below that the BMS blocks charging by design.
Incorrect: connecting before confirming the inverter's DC window. Correct: check 20~29.2V, 40.5~54V or 43.2~57.6V against the inverter datasheet first.
Incorrect: skipping the communication cable because it charges without one. Correct: without CAN or RS485 the inverter cannot read SOC or honour BMS limits.
Incorrect: boxing the unit into a sealed cupboard. Correct: it relies on natural convection with no fans. Leave the clearance specified in the manual or the cells run warm and lose life.
An installer in Andalusia has fitted around thirty 10.24kWh units alongside hybrid inverters since 2025. The main benefit reported was confirming the CAN protocol against each inverter model before ordering, which reduced commissioning issues.
A homeowner in Limassol running two 5.12kWh units reported that pairing worked on first attempt. The LCD is angled such that it can be hard to read when the pack is above shoulder height; this is worth considering when choosing the mounting position.
A distributor in Almaty reported that customers installing in unheated garages encountered the 0°C charging cutoff and assumed a defect. Including a heated-space requirement in quotation documents resolved the complaints.


A: For the 10kWh Home Battery Energy Storage System for Backup and Solar, size to overnight consumption, not daily total. 4-6kWh overnight suits the 5.12kWh unit; 8-10kWh points to the 10.24kWh model.
A: Provide the make and model. The BMS supports RS485, RS232 and CAN; protocol mapping is confirmed before ordering.
A: No. IP20 offers no water protection. Indoor mounting only — garage, utility room, basement or plant room.
A: The DC window. 48V units run 40.5~54VDC, 51.2V units run 43.2~57.6VDC. Match to your inverter's input range.
A: More than 6000 cycles at 0.5C and 25°C with at least 80% capacity retained. Under daily cycling this exceeds fifteen years.
A: Yes, packs of matching voltage and capacity can be paralleled. Provide the target bank size to confirm the configuration.
A: Natural cooling, no fans, no routine servicing. Keep the ventilation clearance clear and check the mounting annually.
A: CE, ROHS and FCC across the range, plus UN38.3, MSDS and ISO9001 on the 25.6V100Ah variant. UN38.3 and MSDS ship with every order.
Address
No. 237, Weisan Road, Yueqing, Zhejiang, China
Tel
Talk Directly to Our EV Charger Factory
Get factory-direct pricing, custom solutions, and expert support.
- Fast Response – Reply within 24 hours.
- OEM/ODM – Flexible customization and sample orders.
- Certified Quality – CE, TÜV, CB, and CCC options.
- Custom Quotes – Tailored to your specifications.
- Technical Support – Expert help with OCPP, DLB, and system integration.