Products

OEM Wall-Mounted DC Chargers for Custom Electric Vehicle Charging Solutions

As electric vehicle adoption accelerates across residential, commercial, and fleet sectors, the demand for reliable and space-efficient charging infrastructure continues to rise. Wall-Mounted DC Chargers have emerged as a preferred solution for locations where floor space is limited but high charging power is still required. AMPPAL, a recognized brand in EV charging technology, designs wall-mounted DC fast chargers that combine robust performance with a slim, space-saving profile. These units deliver direct current directly to the vehicle battery, bypassing the onboard charger and significantly reducing charging times compared to AC alternatives. Whether installed in a private garage, a workplace parking lot, or a commercial depot, AMPPAL wall-mounted DC chargers provide a professional-grade charging experience without the footprint of traditional floor-standing stations.


AMPPAL has spent years refining its DC charging hardware to meet the rigorous demands of daily use. The wall-mounted series is engineered for easy integration into existing electrical infrastructure while maintaining high efficiency and safety standards. Each unit undergoes extensive testing to ensure consistent performance across a wide range of environmental conditions. The brand focuses on practical innovations such as modular power stages, intelligent thermal management, and seamless connectivity, making these chargers suitable for both single-vehicle and multi-vehicle installations.

Product Range and Core Parameters

The AMPPAL wall-mounted DC charger lineup includes four primary power tiers: 20 kW, 30 kW, 40 kW, and 60 kW. Each model shares a common architectural platform, allowing operators to scale charging capacity without changing the physical footprint. The following list outlines the core electrical parameters common to the series:

  • Rated Power: 20 kW, 30 kW, 40 kW, or 60 kW depending on model
  • Input Voltage: 400 VAC ±15%, three-phase, 50/60 Hz
  • Output Voltage Range: 150 VDC to 1000 VDC, suitable for both 400V and 800V battery platforms
  • Maximum Output Current: Up to 200 A on the 60 kW model; lower models scale proportionally
  • Power Factor: ≥0.99 at full load
  • Efficiency: ≥95% at nominal output
  • Standby Power Consumption: Less than 10 W
  • DC Output Accuracy: ±1% for voltage and current
  • Ripple Voltage: Less than 1% peak-to-peak

These parameters ensure that each AMPPAL wall-mounted DC charger delivers stable, clean power to the vehicle battery, minimizing stress on battery management systems and extending overall battery life. The wide output voltage range makes the series compatible with a broad spectrum of electric vehicles, from compact city cars to heavy-duty electric vans.

Technical Specifications at a Glance

The table below provides a detailed comparison of the four AMPPAL wall-mounted DC charger models. This information is critical for installers and fleet managers who need to match charger capacity with site electrical supply and vehicle requirements.

Parameter WDC-20 WDC-30 WDC-40 WDC-60
Rated Power 20 kW 30 kW 40 kW 60 kW
Input Voltage 400 VAC ±15% 400 VAC ±15% 400 VAC ±15% 400 VAC ±15%
Max Input Current 32 A 48 A 63 A 100 A
Output Voltage Range 150–1000 VDC 150–1000 VDC 150–1000 VDC 150–1000 VDC
Max Output Current 67 A 100 A 133 A 200 A
Connector Type CCS2 / CHAdeMO / GB/T optional CCS2 / CHAdeMO / GB/T optional CCS2 / CHAdeMO / GB/T optional CCS2 / CHAdeMO / GB/T optional
Cable Length 3.5 m or 5 m 3.5 m or 5 m 3.5 m or 5 m 3.5 m or 5 m
Dimensions (H x W x D) 650 x 400 x 220 mm 650 x 400 x 220 mm 700 x 450 x 250 mm 750 x 500 x 280 mm
Weight 35 kg 38 kg 45 kg 55 kg
Cooling Method Forced air Forced air Forced air + smart fan Forced air + smart fan
Protection Rating IP54 / IK10 IP54 / IK10 IP54 / IK10 IP55 / IK10
Operating Temperature -30°C to +55°C -30°C to +55°C -30°C to +55°C -30°C to +55°C
Communication OCPP 1.6J, Ethernet, Wi-Fi, 4G OCPP 1.6J, Ethernet, Wi-Fi, 4G OCPP 1.6J, Ethernet, Wi-Fi, 4G OCPP 1.6J, Ethernet, Wi-Fi, 4G
Certifications CE, TUV, UKCA CE, TUV, UKCA CE, TUV, UKCA CE, TUV, UKCA

All AMPPAL wall-mounted DC chargers use a rugged aluminum alloy enclosure with anti-corrosion coating. The internal power modules are hot-swappable on the 40 kW and 60 kW models, reducing downtime during maintenance. The compact dimensions allow installation in spaces as narrow as 400 mm, making them ideal for underground parking garages and tight service bays.

Installation Requirements and Site Planning

Proper installation is critical for safe and efficient operation. AMPPAL provides detailed site preparation guidelines for every wall-mounted DC charger. Before installation, the following conditions should be verified:

  • Electrical Supply: A dedicated three-phase circuit with appropriate breaker rating matching the charger input current. Voltage fluctuations must not exceed ±15% of nominal 400 VAC.
  • Wall Strength: The mounting wall must support at least four times the charger weight. Concrete or brick walls are recommended. For hollow block walls, a steel mounting plate is required.
  • Mounting Height: The charger display and connector holster should be positioned between 1.2 m and 1.5 m from the finished floor for comfortable user access.
  • Clearance: Maintain at least 300 mm of clearance on all sides for ventilation and cable management. The front area should allow a full cable bend radius without straining.
  • Grounding: A dedicated low-impedance grounding conductor must be connected to the charger ground terminal. Ground resistance should be less than 4 ohms.
  • Network Access: For smart charging features, a wired Ethernet port or reliable 4G signal is recommended at the installation location.

AMPPAL wall-mounted DC chargers ship with a mounting template, wall anchors, and a quick-start guide. The terminal block is front-accessed after removing a sealed cover, and all connections are clearly labeled to simplify wiring. A qualified electrician should perform the installation in accordance with local electrical codes and the AMPPAL installation manual.

Safety and Protection Features

Safety is a non-negotiable aspect of DC fast charging. AMPPAL integrates multiple layers of protection into every wall-mounted DC charger to safeguard both users and vehicles. The following protective mechanisms are active during all charging sessions:

  • Overcurrent Protection: Real-time current monitoring with fast-acting circuit interruption prevents damage from short circuits or overloads.
  • Overvoltage and Undervoltage Protection: Input and output voltage are continuously monitored. The charger disconnects instantly if safe limits are exceeded.
  • Ground Fault Detection: Residual current monitoring detects AC and DC leakage currents. The system triggers a shutdown at leakage levels above 6 mA DC or 30 mA AC.
  • Overtemperature Protection: Multiple temperature sensors on power modules and the main control board trigger derating or shutdown to prevent thermal damage.
  • Lightning Protection: Surge protection devices rated for 40 kA (8/20 µs) protect against transient voltage spikes from lightning strikes or grid switching.
  • Emergency Stop: A clearly marked emergency stop button allows immediate manual shutdown. The button meets ISO 13850 standards.
  • Connector Lock: The charging connector locks in place during an active session. It only releases after the charging process is properly terminated or the vehicle unlocks the port.
  • Insulation Monitoring: Continuous insulation resistance checks between DC output and ground ensure safe operation even in wet or humid environments.

These safety features are tested under extreme conditions in AMPPAL's in-house laboratory. The chargers are designed to fail safe, meaning any detected anomaly results in a controlled power-down rather than an uncontrolled event. This level of protection builds confidence for unattended charging in public and semi-public locations.

Smart Connectivity and Network Integration

Modern EV charging infrastructure requires more than just power delivery. AMPPAL wall-mounted DC chargers come equipped with advanced connectivity options that enable remote management, usage tracking, and integration with energy management systems. Each unit supports the Open Charge Point Protocol (OCPP) 1.6J, allowing compatibility with a wide range of back-end software platforms.

Key connectivity features include:

  • OCPP 1.6J Compliance: Standardized communication for remote start/stop, firmware updates, diagnostics, and transaction data logging.
  • Ethernet and Wi-Fi: Local network connections provide low-latency control in commercial buildings and depots.
  • 4G LTE Module: Embedded cellular connectivity ensures the charger remains online even without a local area network. SIM card slot is accessible from the front panel.
  • Load Management: Dynamic load balancing allows multiple chargers on the same electrical service to share available capacity intelligently. This prevents circuit breaker trips and reduces peak demand charges.
  • RFID Authentication: An integrated RFID reader supports ISO 14443 A/B cards, enabling user identification and billing in shared parking environments.
  • Smartphone App Integration: AMPPAL provides a dedicated app for end users to start sessions, monitor charging progress, and view session history.
  • Energy Metering: MID-certified energy meters are available as an option, providing billing-grade measurement for public or workplace charging.

Fleet operators will appreciate the detailed reporting capabilities accessible through the AMPPAL cloud portal. Real-time status, energy consumption per vehicle, and fault alerts are all visible in a single dashboard. The open API allows custom integration with third-party fleet management software, making these wall-mounted DC chargers a flexible component of any charging ecosystem.

Application Scenarios for AMPPAL Wall-Mounted DC Chargers

The versatility of AMPPAL wall-mounted DC chargers makes them suitable for a wide range of use cases. Their compact form factor and high charging speed address the pain points of space-constrained locations while delivering rapid energy replenishment.

Typical installation environments include:

  • Residential Complexes: Apartment and condominium parking garages can offer DC fast charging without sacrificing parking spaces. The 20 kW and 30 kW models are ideal for overnight top-ups and daytime opportunity charging.
  • Workplace Parking Lots: Employers can provide fast charging for employees who need to add significant range during an eight-hour workday. The 40 kW model balances charging speed with moderate electrical infrastructure costs.
  • Fleet Depots: Delivery vans, taxis, and ride-hailing vehicles benefit from the 60 kW charger's ability to add 100 km of range in under 30 minutes for most vehicles. Wall mounting keeps the depot floor clear for vehicle movement.
  • Retail and Hospitality: Hotels, shopping centers, and restaurants can attract EV-driving customers by offering fast charging in their parking facilities. The slim design integrates well with building aesthetics.
  • Public Parking Garages: Municipal and private parking operators can deploy multiple wall-mounted units along walls and columns, maximizing the number of charging points per square meter.
  • Car Dealerships and Service Centers: Technicians can quickly charge vehicles during pre-delivery inspections and service appointments without needing a dedicated charging bay.

AMPPAL's wall-mounted DC chargers are also suitable for retrofitting existing parking structures. Because no floor excavation or pedestal mounting is required, installation can be completed in a matter of hours rather than days. The chargers operate quietly, with noise levels below 60 dB at one meter, making them acceptable for noise-sensitive residential and office environments.

Frequently Asked Questions

Q: What is the typical installation height and wall load requirement for an AMPPAL wall-mounted DC charger?

A: The recommended mounting height for the charger display and connector holster is between 1.2 m and 1.5 m from the finished floor. This range ensures comfortable access for users of varying heights. The wall structure must be able to support at least four times the charger weight, which means a minimum load capacity of 140 kg for the 35 kg WDC-20 model and 220 kg for the 55 kg WDC-60 model. Concrete or solid brick walls are ideal. For hollow block or drywall installations, a steel backing plate must be used to distribute the load across multiple studs. AMPPAL provides a mounting template and recommended anchor specifications in the installation manual.

Q: Can AMPPAL wall-mounted DC chargers be installed outdoors?

A: Yes. All AMPPAL wall-mounted DC chargers carry an IP54 or IP55 ingress protection rating, which means they are protected against dust and water jets from any direction. The enclosures are made from corrosion-resistant aluminum alloy and are tested for operation in temperatures from -30°C to +55°C. For outdoor installations, a small protective canopy or roof overhang is recommended to shield the charger from direct sunlight and heavy rain, although the unit can withstand direct exposure. The connector holster is designed to prevent water accumulation, and all external seals are UV-stabilized to prevent degradation. If the charger is installed in a coastal area with high salt exposure, AMPPAL offers an optional marine-grade coating for additional corrosion protection.

Q: What charging connectors are compatible with AMPPAL wall-mounted DC chargers?

A: AMPPAL wall-mounted DC chargers support the three most common DC fast charging connector standards: CCS2 (Combined Charging System Type 2), CHAdeMO, and GB/T. Each charger can be configured with one or two connectors depending on the model and regional requirements. The CCS2 connector is standard for European and North American markets, while CHAdeMO is widely used by Japanese and some older EV models. GB/T is required for the Chinese market. The 20 kW and 30 kW models typically have a single connector, while the 40 kW and 60 kW models can be ordered with dual connectors for simultaneous charging of two vehicles, with power shared dynamically between them. AMPPAL uses liquid-cooled cables on the 60 kW dual-connector version to maintain safe operating temperatures during extended high-current sessions.

Q: How does the dynamic load balancing work on AMPPAL wall-mounted DC chargers?

A: Dynamic load balancing is a built-in feature that allows multiple AMPPAL chargers on the same electrical service to share available capacity without exceeding the site's maximum demand limit. A master unit or an external energy meter monitors the total current draw of the building or charging group. When the total load approaches the configured limit, the chargers automatically reduce their output power to keep the system within safe bounds. For example, if a site has a 100 A service and two 60 kW chargers, the load balancing system might limit each charger to 30 kW when both are active, but allow a single charger to use the full 60 kW when the other is idle. This intelligent allocation prevents circuit breaker trips, reduces peak demand charges from the utility, and enables more chargers to be installed on existing infrastructure without costly electrical upgrades. The load balancing parameters are configurable through the AMPPAL cloud portal or locally via the charger's maintenance interface.

Q: What communication protocols are supported for fleet management integration?

A: AMPPAL wall-mounted DC chargers support OCPP 1.6J, which is the industry standard for open communication between EV chargers and central management systems. This allows seamless integration with third-party fleet management platforms such as those used by logistics companies, ride-hailing services, and municipal transit operators. Additionally, the chargers support Modbus TCP for local building management system integration and MQTT for lightweight IoT data streaming. The AMPPAL cloud platform provides a RESTful API that enables custom software development for fleet-specific needs such as driver authentication, vehicle-to-charger assignment, and energy usage reporting by cost center. All communication channels are secured with TLS encryption, and the charger's firmware can be updated remotely over any of the supported network interfaces. For fleets with mixed charger brands, OCPP compliance ensures that the AMPPAL unit can be controlled by a universal charge management system without proprietary lock-in.

Q: How often do AMPPAL wall-mounted DC chargers require maintenance?

A: AMPPAL wall-mounted DC chargers are designed for minimal routine maintenance. The fully sealed enclosure and contactless internal components reduce the need for periodic cleaning or part replacement. Recommended maintenance intervals are as follows: every 6 months, perform a visual inspection of the enclosure, connector, and cable for signs of wear or physical damage; every 12 months, check all electrical connections and torque values according to the maintenance manual; every 24 months, replace the air filter on models with forced-air cooling (the filter is user-replaceable and takes less than five minutes to swap). The internal power modules on the 40 kW and 60 kW models are hot-swappable, so if a module fails, it can be replaced without powering down the entire charger. AMPPAL offers a standard 3-year warranty on all wall-mounted DC chargers, with optional extended warranty packages up to 7 years. The cloud platform also provides predictive maintenance alerts based on internal sensor data, allowing operators to address potential issues before they cause downtime.

View as  
 
7kW Wall-Mounted DC EV Fast Charger for Home and Workplace

7kW Wall-Mounted DC EV Fast Charger for Home and Workplace

A 7kW Wall-Mounted DC EV Fast Charger for Home and Workplace that runs on ordinary single-phase 220V power. Built for villas, small workshops and roadside shops that want real DC charging without a three-phase upgrade. Factory-direct from AMPPAL, OEM and ODM welcome.
40kW High-Power Wall-Mounted DC EV Charger for Fleet Depots

40kW High-Power Wall-Mounted DC EV Charger for Fleet Depots

40kW High-Power Wall-Mounted DC EV Charger for Fleet Depots delivers 40kW DC charging at 0-133A from a wall bracket measuring 450 × 660 × 240mm. For underground car parks, leased forecourts and tight urban sites where a floor-standing cabinet will not fit or is not permitted.
30kW Compact Wall-Mounted DC EV Charger for Dealerships and Workshops

30kW Compact Wall-Mounted DC EV Charger for Dealerships and Workshops

30kW Compact Wall-Mounted DC EV Charger for Dealerships and Workshops delivers a full 0-100A across 200-1000VDC. Sized for operators who bill per kWh and need two to three sessions per bay per day without a floor-standing cabinet.
20kW Wall-Mounted DC Fast EV Charging Station for Commercial Parking

20kW Wall-Mounted DC Fast EV Charging Station for Commercial Parking

20kW Wall-Mounted DC Fast EV Charging Station for Commercial Parking is a compact DC charger on a 380V three-phase supply, delivering 0-67A output across a 200-1000VDC window. The lowest-cost way into genuine three-phase DC charging for depots, hotels and small commercial car parks.
AMPPAL is a professional Wall-Mounted DC Chargers manufacturer and supplier in China. We provide high quality products with advanced manufacturing capabilities and customized services for different application requirements.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept