" "
Whatsapp
Ask an operator who has spent three years on a closed charging system, and the pain starts on migration day. The hardware worked; the software refused to leave. Open OCPP 1.6J exists to prevent exactly that conversation.
The AMPPAL 22kW Slim Tower AC EV Charger for Residential and Commercial Properties (AF-AC-022-Y-A-0-4-JA-P) delivers 22kW through two Type 2 guns (16A+16A) from a 300 x 150 x 1400mm column with a 5-inch touch screen. Its real differentiator sits in the firmware: every transaction, session, and status event speaks standard OCPP 1.6J.
That means the tower is not married to our cloud, our app, or any reseller's portal. You point it at the platform you choose today, and again in three years when a better one appears.
Closed systems feel easy at first: the app is polished, setup is a QR code. The bill arrives later, in exit fees, repurchased hardware, or data sitting on a server you do not control.

No vendor lock-in: if the platform raises fees or goes offline, the hardware stays yours and moves on.
Roaming-ready: aggregators and partner networks accept the same protocol your back office already speaks.
Tariff control stays with you: you set prices per connector through the platform, not through a factory-bound app.
Remote operations: start/stop, reservations, and firmware updates ride the same OCPP channel as metering data.
Auditable records: every kWh and transaction ID is logged in a standard format accountants and regulators can read.
Future-proofing: when solar or smart charging arrives later, most OCPP-based energy management systems can read this tower's live data.
Open tendering: if your company must re-tender the charging service, an open-protocol network is easier to hand over, value, and audit.
|
Parameter |
Specification |
|
Model |
AF-AC-022-Y-A-0-4-JA-P |
|
Rated Power |
22kW |
|
Input Voltage |
380VAC ±15% |
|
Rated Current |
16A+16A |
|
Dimensions |
300 × 150 × 1400 mm |
|
User Interface |
5" Color Touch Screen |
|
Network Protocol |
OCPP 1.6J |
|
Communication |
Ethernet, 4G, WiFi |
|
Protection Grade |
IP54 |
|
Operating Temp |
-20°C to +50°C |
|
Certification |
CE Compliance |
|
Warranty |
2 Years |
CPOs that tender their back office every two or three years and need chargers that survive the swap.
Fleets that connect to the parent company's existing OCPP server instead of running a second system.
Hotels and malls that want to roam with several apps, not be bound to one operator's app.
Property developers who install now and sell the charging rights later; the buyer inherits open hardware.
Government street-charging tenders that require open standards in the specification.
Operators testing a new aggregator on ten towers before committing the whole network.

The tower keeps two conversation channels open: Ethernet as the primary link, plus 4G and WiFi as fallbacks. It dials out to your server, so no port forwarding or static public IP is needed on your side.
When a car plugs in, the station sends a BootNotification, then status and transaction updates as the session runs. OCPP 1.6J handles both charge point management and transaction handling cleanly for AC charging.
Migration is a configuration change, not a hardware change: open the station menu, enter the new server URL and credentials, reboot. Our engineers can walk your IT person through the switch in under an hour, usually remotely.
Worth knowing: the tower keeps its local metering and session log regardless of which server it talks to. Even if a platform disappears overnight, you still have the charging history stored on the device for export.
CE per the Low Voltage and EMC directives, reverified on every production batch.
OCPP 1.6J conformance is tested against a reference server in our lab before units leave the line.
100% hi-pot dielectric testing and ground continuity checks on the final station.
IEC 60068 thermal cycling from -30°C to +70°C and 96-hour salt spray on sampled units.
48-hour full-load burn-in while the comms link is monitored for dropouts and reconnect behaviour.
RoHS/REACH compliant components under an ISO 9001:2015 quality system; the factory also holds CCC, TÜV, UL, and CB certificates on other product lines.
CNC laser cutting of the column shell, 0.1mm tolerance.
Press-brake folding and seam welding of the 1400mm tower body.
FANUC robot welding of the base plate and cable gland brackets.
Three-stage surface cleaning and finishing before assembly.
DIN-rail assembly: contactors, RCD, and metering module, torqued to spec.
Electronics bay: touch screen, comms board, and power board fitted.
Firmware flashing and OCPP conformance run against our test server; the test log is stored per serial number.
Hi-pot, visual QC, and packing; standard orders ship in 15-20 working days.
Check one: does your current platform actually matter to you? If you run a single site with a proprietary app you are happy with, a closed charger is cheaper, and this tower's freedom is money you will not use.
Check two: what protocol version does your back office speak? This station runs OCPP 1.6J, which covers the overwhelming majority of AC charging needs; if your roadmap requires OCPP 2.0 features such as ISO 15118 plug-and-charge, tell us before you order so we can advise on the right model.
Check three: who holds the roaming relationship? If an aggregator will route your sessions, ask them for their OCPP server details first; most accept 1.6J endpoints, and the tower can join their network within a day.
One more honest note: open protocol protects you from lock-in, not from bad wiring. The 22kW tower still needs a proper 380VAC three-phase feed, a correctly sized breaker, and a grounded installation; no firmware can fix a loose neutral.
Protocol honesty: OCPP 1.6J conformance is verified per batch in our lab, and we will share the test log.
Hardware headroom: two 16A sockets on one 380VAC feed, 5-inch screen, IP54, -20°C to +50°C operating range.
Terms: MOQ 1 unit on standard models, 15-20 working days lead time, 2-year warranty.
Global reach: exports to 40+ countries, CE documentation included, spare parts via DHL/FedEx.
OEM/ODM depth: we have built AC and DC lines for brands across the Middle East, Europe, and Southeast Asia since 2014.
Order a container and you get the same honest packing every time: one tower per 5-ply carton, foam corner blocks, anchor kit and glands inside, about 45kg gross per box.
Four cartons to a pallet with edge protectors and shrink wrap; a 40-foot container carries roughly 60 towers palletized or up to 80 floor-loaded, so freight per unit stays predictable for your quotation.
We quote FOB Ningbo or Shanghai (EXW available) and hand over the commercial invoice, packing list, bill of lading, certificate of origin, and CE declaration of conformity with each shipment.
Mixed containers are welcome: towers share space with our wall-mounted AC units.
2-year warranty on manufacturing defects, counted from the shipment date.
24-hour technical response; our engineers have joined platform migration calls for clients in four time zones.
Spare parts via DHL/FedEx within 2 working days for common items.
Photo-and-serial RMA: we confirm replacement or repair before you return anything.
Free documentation pack: OCPP connection guide, sample server configuration, and a test endpoint for your IT team.
Firmware release notes list which OCPP messages changed, so your platform team can test before rollout.
Wrong: changing the server URL while a session is running. Right: migrate when the connector is idle and reboot the tower after the switch.
Wrong: assuming WiFi alone is enough for a public network. Right: wire the primary link with Ethernet and keep 4G as the fallback.
Wrong: leaving default credentials in the station menu. Right: set a strong password on day one; the OCPP connection is only as safe as the device credentials.
Wrong: testing one platform and assuming the rest behave the same. Right: run a 24-hour trial on the new server with one tower before switching the fleet.
Wrong: ignoring clock sync. Right: keep NTP enabled, because transaction logs with skewed timestamps cause billing disputes later.
Wrong: treating firmware updates as optional. Right: schedule updates on idle connectors, because fixes often target exactly the edge cases field operators report.
A charge point operator in Croatia moved 30 towers from one platform to another in a single weekend. Their technical lead said the switch was a URL change per unit, and the only delay was their own DNS. They now trial a new aggregator on five towers before any contract renewal.
A Malaysian logistics firm tied the towers into the group's existing OCPP server instead of running a second back office. Their IT manager's complaint: the 5-inch screen shows English only, so drivers occasionally need the mobile app for instructions in Malay.
A Turkish operator, part of a partnership we have supplied since 2022, uses the towers for kerbside charging in Istanbul. The 4G fallback saved them twice during local fiber cuts; sessions kept billing correctly because the station queued records and uploaded them when the link returned.
What repeats across these reports: nobody budgets for a protocol change, and the towers that survive it quietly are the ones nobody had to touch.

A: Any platform implementing the 1.6J AC charging profile; we keep a short list of tested servers and add yours on request.
A: Yes, each tower registers as its own charge point with its own identity.
A: The session continues and the record is queued locally, then uploaded when the link returns.
A: Yes, the same 300 x 150 x 1400mm body as our 14kW and 44kW towers.
A: No, firmware is free during the warranty period and delivered over the OCPP channel or as a local file.
A: Yes, logo, startup screen, and packaging are customized under an OEM agreement.
A: Each socket delivers up to 16A per phase, about 11kW on 380V three-phase; the 22kW nameplate is the two-gun total.
A: A touch screen, a comms board, and a set of cable glands cover most field repairs; we suggest one kit per 20 towers.
Address
No. 237, Weisan Road, Yueqing, Zhejiang, China
Tel
Talk Directly to Our EV Charger Factory
Get factory-direct pricing, custom solutions, and expert support.
- Fast Response – Reply within 24 hours.
- OEM/ODM – Flexible customization and sample orders.
- Certified Quality – CE, TÜV, CB, and CCC options.
- Custom Quotes – Tailored to your specifications.
- Technical Support – Expert help with OCPP, DLB, and system integration.