Products
480kW Liquid-Cooled DC Fast Charging Power System for Commercial EV Networks
  • 480kW Liquid-Cooled DC Fast Charging Power System for Commercial EV Networks480kW Liquid-Cooled DC Fast Charging Power System for Commercial EV Networks

480kW Liquid-Cooled DC Fast Charging Power System for Commercial EV Networks

AMPPAL 480kW Liquid-Cooled DC Fast Charging Power System for Commercial EV Networks (AF-DC-480-LC-S2) is a 480kW liquid-cooled DC charging stack whose 600A liquid-cooled terminals solve the physical limits of air-cooled cables: thinner, lighter, cooler guns one hand can manage. 94.5% peak efficiency, DC200-1000V, IP54, CCS1/CCS2/GB/T/CHADeMO/NACS, OCPP 1.6/2.0. CE/TUV/CB/CCC/UL certified, 15-20 working days from the Yueqing factory, 2-year warranty. Ask AMPPAL for the AF-DC-480-LC-S2 price and the liquid cable spec sheet.

The 480kW S2 Stack in Plain Terms

The AF-DC-480-LC-S2 is a 480kW charging stack with one deliberate choice: every terminal is liquid-cooled at 600A, and the cooling loop runs through the cable and the gun, not just the power module. The 1850 x 1850 x 1000mm main cabinet feeds current to terminals that stay thin enough for a driver to lift with one hand.

The physics is unforgiving. A 600A DC current through copper needs roughly 240mm² of conductor cross-section; wrapped in insulation, an air-cooled cable of that size weighs about 7-8kg per meter and is stiff enough to fight the user. Push the same current through a thinner cable and the copper passes 90°C within minutes.

Liquid cooling breaks that trade-off. Coolant circulates inside the jacket, carries the heat away at the source, and lets the conductor shrink to a practical size. The result is a gun-and-cable assembly light enough for one-handed plug-in at 600A.

480kW Liquid-Cooled DC Fast Charging Power System for Commercial EV Networks

What 600A Liquid-Cooled Cables Change for Your Site

Single-hand ergonomics: the liquid-cooled gun and cable weigh roughly 60% less than an air-cooled assembly rated for the same current, which matters on 16-hour shift days.

Cable temperature stays near 40°C at 600A continuous, so the rubber jacket does not soften, the connector does not creep, and contact resistance stays stable.

Thinner cables reach further: a 5-meter liquid cable is genuinely flexible, so one terminal serves both front and rear charge ports without a second gun.

The cooling loop is sealed: a small pump and radiator inside the terminal move coolant at a fixed flow rate, with no chiller, no water top-ups and no external plumbing.

Sustained 600A is the point: where air-cooled guns must derate after 15-20 minutes of full current, the liquid terminal holds 600A for as long as the vehicle asks.

The 480kW pool behind it lets two 800V trucks or three sedans draw simultaneously without starving each other.

Technical Specifications

Parameter

Specification

Model

AF-DC-480

Rated Output Power

480kW

Main Cabinet (mm)

1850 × 1850 × 1000

Terminal

600A liquid-cooled

Input Voltage

AC380V±15%

Output Voltage Range

DC200-1000V

HMI

7" touch screen

Peak Efficiency

94.5%

Protection Grade

IP54

Compatible Connectors

CCS1/CHAdeMO/CCS2/GB/T/NACS

Operating Temperature

-25°C ~ +50°C

Warranty

2 Years Standard

Five Site Profiles That Should Look at the S2

Flagship highway chargers where premium EV owners judge the site by handle weight and cable stiffness.

Depot lanes for electric vans and trucks with 800V architectures that pull 600A for 30-60 minutes.

Corridor sites that must sustain back-to-back fast sessions without thermal derating.

Tight urban pads where long, stiff air-cooled cables would block the adjacent bay.

Showcase stations where the operator wants the lowest possible cable weight for elderly drivers.

Inside the Liquid-Cooled Cable Loop

The loop starts inside the terminal: a DC pump pushes coolant through a hose that runs the full length of the cable jacket, wraps the connector contact block, and returns to a small air-cooled radiator. Flow rate and inlet temperature are monitored, and the pump runs whenever the terminal is plugged in, not only during charging.

Heat is removed where it is created. The 600A contact block, the cable conductor and the handle all sit inside the loop, so none of them exceeds roughly 45°C even on a 50°C day. Air cooling, by contrast, dumps heat into the cable jacket and depends on ambient air that may already be hot.

Because the loop is sealed and the coolant is a non-conductive dielectric fluid, there is no water, no corrosion path, and no freeze risk down to -25°C. AMPPAL specifies the fluid and the hose rating, and the circuit is pressure-tested at the factory before crating.

The Paper Trail: Certificates and Test Reports

CE, TUV, CB, CCC and UL certificates cover the AF-DC-480-LC-S2, and the liquid-cooled gun carries its own connector certification.

The coolant circuit is pressure-tested at 2x operating pressure, and the hose assembly is sampled on a 20,000-cycle flex test.

Insulation resistance at 1000VDC and ground continuity are checked on every unit.

Thermal validation runs 600A continuous for 8 hours on the load bank, with probes on cable, gun and connector.

IP54 per IEC 60529 and surge immunity per IEC 61000-4-5 are part of the batch test record.

Test reports ship with the batch for customs, insurance and grid paperwork.

Eight Production Steps for the S2 Cabinet

Enclosure panels are laser-cut on TRUMPF machines and CNC-formed.

Cabinets get the powder-coated outdoor finish.

Power modules assemble on the dedicated DC line.

The liquid-cooled gun and cable are built on a separate clean bench with sealed coolant filling.

Busbars and high-current harnesses are installed with torque-controlled tools.

FANUC robots place modules, and the coolant loop is pressure-tested after wiring.

Firmware and OCPP profiles are flashed and matched to your backend.

A 48-hour load bank burn-in at 480kW precedes final inspection and crating.

Is 600A Worth It? A Straight Answer

Buy the S2 if your site will actually load 600A: 800V trucks, premium sedans, or a corridor with back-to-back fast sessions. That is the only condition where liquid cable hardware pays for itself, usually inside 12-18 months on utilization alone.

Do not buy it if your traffic is 400V cars below 250A. An air-cooled 480kW unit or the mixed-terminal S1 will cost less, and a 600A liquid gun that never sees 600A is a luxury with maintenance. Do not buy it if your team cannot run a 15-minute coolant check every six months.

If you are still weighing the S1 against the S2, remember the S1 keeps air-cooled terminals available while the S2 does not. The S2 is the cleaner long-term answer once you have decided the site is all-premium.

Five Concrete Reasons to Buy the S2 from AMPPAL

The 480kW S2 is built in the same Yueqing factory that supplied 500 liquid-cooled units to the NEOM green hydrogen project in Saudi Arabia.

15-20 working days lead time and a one-unit MOQ for stock configurations.

The full certificate pack and the liquid cable spec sheet ship with the unit.

200+ stations in AMPPAL's own operating network, so field failure data feeds back into the design.

EXW, FOB Ningbo or CIF pricing with a named engineer for the life of the project.

How the S2 Ships: Crating and Container Loading

The S2 main cabinet measures 1850 x 1850 x 1000mm and ships in a reinforced plywood crate rated for top-stacking. Each liquid-cooled terminal travels in its own foam-lined box with the coolant loop pre-filled and sealed.

One S2 with two terminals is the standard 40-foot container layout; the crate is bolted to the floor rails and the terminal boxes are strapped beside it. Gross weight per set is roughly 1300-1500kg.

Shipping documents: commercial invoice, packing list, bill of lading, certificate of origin and batch test reports. We quote EXW, FOB Ningbo or CIF.

Coolant Maintenance Is Part of the Warranty Package

The 2-year warranty covers the stack, terminals, modules and the sealed coolant circuit.

Coolant refill kits and hose clamps ship within 3-5 working days; the factory publishes the fluid spec so you can source locally.

Quarterly remote checks cover coolant temperature trends, which flag pump wear early.

The 6-month service checklist (coolant level, hose clamps, connector wear) is provided in five languages.

A dedicated WhatsApp channel connects you to the after-sales engineer who knows your serial numbers.

Handling Liquid-Cooled Guns: Wrong vs Right

Wrong: Using tap water or generic coolant in the loop. Right: Use only the dielectric fluid AMPPAL specifies; the pump seals and hose rating depend on it.

Wrong: Coiling the liquid cable tightly on the ground between sessions. Right: Let it lie flat or hang on the provided hook; tight coils kink the inner hose.

Wrong: Assuming the terminal cools itself when unplugged. Right: The pump stops when the gun is docked; keep the terminal in shade to avoid heat soak before the next plug-in.

Wrong: Replacing a worn liquid gun with an air-cooled unit from stock. Right: The S2 terminal bay is wired and cooled for liquid guns; use the matched 600A unit.

Wrong: Skipping the six-month check because the loop is sealed. Right: Check level, clamps and connector wear; a failed pump is far cheaper to replace than a melted connector.

Operator Feedback After Six Months of 600A Service

A Dutch corridor operator ran two S2s at a service plaza from August 2025. Their charge point operator measured gun cable temperature at 42°C after a 40-minute 600A session in 28°C ambient, and drivers commented on the light handle. Their complaint: the terminal pedestal is heavy to lift during pad maintenance.

A US site developer testing NACS compatibility said the 5-meter liquid cable reached the rear port of a pickup without repositioning the truck, which they had not expected from a 600A gun. They flagged spare-part lead time as the main risk and ordered one spare terminal with the stack.

An Australian depot running heavy road trucks pushed the S2 at full 600A in three-hour windows. Thermal data held, but the site engineer wanted a longer hose; AMPPAL now offers 7-meter liquid cables as a custom line item.

600A Liquid Cable FAQ

Q: Why is 600A only practical with liquid cooling?

A: At 600A the copper losses reach about 25kW per 100 meters of cable, and air cannot carry that heat out of a hand-held gun.

Q: How heavy is the gun?

A: The full liquid assembly is roughly 60% lighter than an equivalent air-cooled one, light enough for one-handed use.

Q: Does the coolant need changing?

A: Every 2 years or 40, 000 sessions, whichever comes first; the factory supplies the refill kit.

Q: What happens if the pump fails?

A: The terminal derates to a safe level and reports the fault over OCPP; the pump is a field-replaceable part.

Q: Can the S2 charge two 800V trucks at once?

A: Yes, the 480kW pool splits between terminals, and each 600A lane gets what it requests up to the pool limit.

Q: Is the cable long enough for rear ports?

A: The standard is 5 meters, and 7 meters is available as a custom order.

Q: Does cold weather affect the coolant?

A: No. The dielectric fluid is rated to -25°C and the loop is sealed, so there is no freeze risk.

Q: What is the lead time?

A: 15-20 working days for stock configurations after confirmation and deposit.


Send Inquiry
Contact Info

Talk Directly to Our EV Charger Factory

Get factory-direct pricing, custom solutions, and expert support.

- Fast Response – Reply within 24 hours.

- OEM/ODM – Flexible customization and sample orders.

- Certified Quality – CE, TÜV, CB, and CCC options.

- Custom Quotes – Tailored to your specifications.

- Technical Support – Expert help with OCPP, DLB, and system integration.

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept